高频超声及弹性技术评价冈上肌腱修补术后康复效果的应用研究

  

  1. 1.河北医科大学第三医院超声医学科,河北 石家庄 050051; 2.河北医科大学第三医院肩肘专科,河北 石家庄 050051

  • 出版日期:2024-12-25 发布日期:2025-01-03
  • 作者简介:叶辉(1998-),男,云南梁河人,河北医科大学第三医院医师,医学硕士,从事医学超声影像学诊断研究。
  • 基金资助:
    河北省财政厅老年病防治经费资助项目

Application of high-frequency ultrasound and elastography technology in evaluating the rehabilitation effect after supraspinatus tendon repair

  1. 1.Department of Ultrasound Medicine, the Third Hospital of Hebei Medical University, Shijiazhuang 050051, China; 2.Department of Shoulder and Elbow, the Third Hospital of Hebei Medical University, Shijiazhuang 050051, China

  • Online:2024-12-25 Published:2025-01-03

摘要: 目的 探讨高频超声及弹性成像技术随访冈上肌腱修补术后康复效果的应用价值。
方法 收集因单纯冈上肌腱撕裂在河北医科大学第三医院肩肘专科行关节镜下肩袖修补术的患者39名,回顾分析术后1个月、3个月、6个月高频超声及弹性成像技术测量冈上肌腱厚度、宽度及剪切波速度(shear wave velocity,SWV)的结果,同时收集患者的视觉模拟评分法(visual analog scale,VAS)评分、Constant-Murley肩关节评分。比较术后不同时期冈上肌腱超声指标的变化,分析超声指标与VAS评分的相关性,并依据Constant-Murley评分70为界,分析各超声指标对康复效果的判断效能。
结果 术后各时期两两比较,患侧冈上肌腱宽度差异均无统计学意义(P>0.05);术后1个月与3个月、1个月与6个月患侧冈上肌腱厚度差异有统计学意义(P<0.05),术后3个月与6个月患侧冈上肌腱厚度差异无统计学意义(P>0.05);术后1个月与3个月、3个月与6个月、1个月与6个月患侧冈上肌腱SWV值差异有统计学意义(P<0.05)。术后1个月患侧与健侧冈上肌腱厚度及SWV值差异有统计学意义(P<0.05),宽度差异无统计学意义(P>0.05);术后3个月及6个月患侧与健侧冈上肌腱SWV值差异均有统计学意义(P<0.05),厚度及宽度差异均无统计学意义(P>0.05)。Spearman相关性分析显示SWV值与肩关节VAS评分呈中等正相关(rs=0.791,P<0.001),而厚度及宽度与肩关节VAS评分无显著相关性。依据Constant-Murley评分70为界,SWV值的曲线下面积为0.781,厚度及宽度曲线下面积为0.531、0.466。
结论 高频超声及弹性成像技术能够实时评估患者冈上肌腱术后形态及硬度的变化情况,其中SWV在评价VAS及判断功能康复效果方面具有一定的参考价值,有助于临床医师及康复医师制定合适的康复计划。


关键词: 肩损伤, 高频超声, 弹性成像

Abstract: Objective To explore the application value of high-frequency ultrasound and elastography technology in following up the rehabilitation effect after supraspinatus tendon repair. 
Methods A total of 39 patients who underwent arthroscopic rotator cuff repair due to simple supraspinatus tendon tear in the Department of Shoulder and Elbow, the Third Hospital of Hebei Medical University were enrolled. The results of high-frequency ultrasound and elastography technology measuring the thickness, width and shear wave velocity(SWV) of the supraspinatus tendon at 1 month, 3 months and 6 months after surgery were retrospectively analyzed. The visual analog scale (VAS) score and Constant-Murley shoulder joint score of the patients were also collected. The changes of ultrasound indicators of supraspinatus tendon at different periods after surgery were compared, the correlation between ultrasound indicators and VAS scores was analyzed, and the judgment efficiency of each ultrasound indicator for the rehabilitation effect was analyzed based on the Constant-Murley score of 70. 
Results When comparing each other at each postoperative period, there was no significant difference in the width of the supraspinatus tendon on the affected side (P>0.05), while there was a significant difference in the thickness of the supraspinatus tendon on the affected side between 1 month and 3 months after surgery, and between 1 month and 6 months after surgery(P<0.05). There was no significant difference in the thickness of the supraspinatus tendon on the affected side between 3 months and 6 months after surgery (P>0.05). The difference in SWV value of supraspinatus tendon on the affected side was significant between 1 month and 3 months after surgery, between 3 months and 6 months after surgery, and between 1 month and 6 months after surgery (P<0.05).The difference in thickness and SWV value of the supraspinatus tendon between the affected side and the healthy side was significant at 1 month after surgery (P<0.05), but the difference in width was not significant (P>0.05). At 3 months and 6 months after surgery, the difference in SWV value of the supraspinatus tendon between the affected side and the healthy side was significant (P<0.05), but there was no significant difference in the thickness and width (P>0.05). Spearman correlation analysis showed that the SWV value had a moderate positive correlation with the VAS score of the shoulder joint (rs=0.591, P<0.001), while the thickness and width had no significant correlation with the VAS score of the shoulder joint. Based on the Constant-Murley score of 70, the area under the curve (AUC) of the SWV value was 0.781, and the AUC of the thickness and width was 0.531 and 0.466 respectively. 
Conclusion High-frequency ultrasound and elastography technology can evaluate the changes in postoperative morphology and stiffness of patients' supraspinatus tendon in a timely manner. SWV has certain reference value in evaluating VAS and judging the effect of functional rehabilitation, which is helpful to clinicians and rehabilitation physicians to develop an appropriate rehabilitation plan.

Key words: shoulder injuries, high-frequency ultrasound, elastography