›› 2014, Vol. 35 ›› Issue (9): 1040-1040.

• 论文 • 上一篇    下一篇

高效液相色谱法测定血浆中瑞芬太尼含量

冯锐;郑颖;张俊贞;王明霞;刘江;尉晓然   

  1. 河北医科大学第四医院药学部,河北 石家庄,050011
  • 发布日期:2014-09-25

ZHU Chunhua;WEN Ya;WANG Lina;JI Hui;YANG Yi;LIU Ying

FENG Rui;ZHENG Ying;ZHANG Junzhen;WANG MingXia;LIU Jiang;YU Xiaoran   

  • Published:2014-09-25

摘要: 目的:建立血浆中瑞芬太尼高效液相色谱测定方法,为临床合理用药提供依据。方法血浆样品用1-氯丁烷进行萃取,上清液提取至0.01mol/L盐酸溶液中。分析柱为spherisorb-CN,流动相为0.02mol/L的NaH2 PO4水溶液-乙腈(70:30),内含三乙胺0.01%,流速1.5mL/min,柱温为室温,紫外检测波长为210nm,进样量为200μL。选择择期行胸科手术患者8例,靶控输注瑞芬太尼浓度( Cp)6μg/L复合异丙酚2.5mg/kg,分别在瑞芬太尼靶控输注前及靶控输注后5、10、20、30、60、90min时抽取桡动脉血,用高效液相色谱法测定瑞芬太尼血药浓度(Cm)。结果人血浆中瑞芬太尼检测浓度在2.5~300μg/L范围内线性关系良好(r=0.9991)。日内日间精密度均在10%以内,提取回收率大于78.57%,方法回收率在96.03%~104.67%。在靶控输注5~20min时,瑞芬太尼测定浓度低于靶控输注浓度( p<0.05),30~90min两者差异无统计学意义( p>0.05)。结论该方法操作简便,分离度好,其专属性、准确度、精密度、线性范围及稳定性均适合实际样品的检测。

关键词: 瑞芬太尼, 血浆, 色变法, 高压液相

Abstract: OcjectiVe High performance liquid chromarography ( HPLC ) method was established for determination of remifentanil in plasma. The study will provide academic foundation for the development and clinical use of remifentanil. Methods The samples eXtracted with 1-chlorobutane and supernatant was back eXtracted into 0. 01mol/L HCl again. The separation was performed on a spherisorb-CN column with a mobile phase of 0. 02mol/L-1NaH2 PO4-acetonitrile( 70: 30 ) including 0. 01%triethylamine at a flow rate of 1. 5mL/min. The column temperature was room temperature,the detection-wavelength was 210nm and 200μL of solution was injected into HPLC. Eight patients undergoing thoracic surgery were assigned to receive remifentanil target controlled infusion( TCI )( 6μg/L ) and propofol intravenous injection(2. 5mg/kg). Arterial blood samples were taken before and after TCI remifentanil 5, 10,20,30,60,90 min for measuring of blood concentration of remifentanil by HPLC. Results A linearity was obtained from 2 . 5μg/L to 300μg/L of remifentanil in plasma with a good correlation( r=0 . 999 1 ). The between-day and within-day RSD% were less than 10%. The eXtraction recoveries were more than 78 . 57%,and the method recoveries were between 96 . 03% and 104 . 67%. The determination of the concentration was lower than target plasma concentration at TCI 5 min to 20 min( p<0 . 05 )and there was no significant difference from 30 min to 90 min( p >0 . 05 ). Conclusion This HPLC method is simple,sensitive and accurate,and it is suitable for routine determination of remifentanil levels in human plasma.

Key words: remifentanil, plasma, chromatography, high pressure liquid

中图分类号: